Lift off! Easy and Safe lifting for PVC Cabinet

The Challenge of Installing Large Electrical Cabinets

In recent years, external electrical enclosures have become larger. The increase in size also means enclosures have become more difficult to transport and install.

To improve the design and safety of Ritherdon Enclosures, the size and weight of the Cabinets and Feeder Pillars, as well as their net load, have been carefully considered. The design team added removable lifting rails. This makes it easier and safer to move the cabinets for transport and installation.

Ritherdon has recently added the PVC Cabinet to the range of electrical enclosures, incorporating this design feature into the cabinet. The PVC Cabinet has a reinforced structural subframe with integral lifting points for easy and safe lifting. 

Read further on innovation behind the PVC Cabinet.

Safe Lifting Means a Safe Installation

There is no need for DIY solutions, as the removable lifting rails with high tensile screws have already been included. Lifting loads have been calculated, meaning the PVC Cabinet is designed for safe and easy lifting.

How to Lift a Cabinet Properly?

  • Include lifting points in the Cabinet’s design.
  • Use correct lifting rails and high tensile screws.
  • Ensure even weight distribution during lifting to prevent instability.
  • Use appropriate lifting equipment, such as hoists or forklifts, rated for the cabinet’s weight.

What Are High Tensile Screws?

High tensile screws are used for applications that require high stress fastening to ensure safe and reliable lifting.

Understanding Cabinet Weight and Load Capacity

Before lifting, it is important to understand both the weight of the empty cabinet and how much it can hold when filled or populated (net load).

The PVC Cabinet’s reinforced structural subframe allows it to be safely lifted even when fully populated, with a safe lifting load exceeding 500 kg.

The size of the chosen PVC Cabinet determines its weight, as the range includes six sizes (or three sizes, each with two depth choices). Please see the Data Tab under the PVC Cabinet product page for more information. 

PVC Cabinet being hoisted safely using lifting lugs by a forklift truck

Installation Best Practices: Mounting the PVC Cabinet

Once lifted into position, follow these steps for a safe and proper installation:

Step 1: Preparing the Base

  • Ensure the plinth is level and has concrete has fully cured.

Step 2: Positioning the PVC Cabinet

  1. Carefully position the PVC Cabinet onto the Plinth.
  2. Align the mounting holes at the base of the Cabinet with those on the Plinth.

Step 3: Securing the Cabinet

  1. Insert the supplied fixing bolts through the holes in the Cabinet base and into the Plinth.
  2. Tighten securely using a spanner or socket set.
  3. Ensure the Cabinet is level and properly aligned.
  4. Verify that the Cabinet door operates smoothly and locks securely.

For further detail, see full installation instructions. 

Removing the Lifting Rails

Steps to Remove the Lifting Rails:

  1. After installation, detach the lifting rails by removing the high tensile screws securing them to the Cabinet.
  2. Replace the high tensile screws with the supplied stainless steel screws to effectively seal the holes.
  3. Install plastic caps over the screws to maintain electrical insulation and a professional finish.

Why Removing the Lifting Rails Matters

After securing the cabinet in place, removing the lifting rails and installing plastic caps serves two key purposes:

  1. A Professional, Streamlined Finish
  • The cabinet maintains a clean and professional appearance.
  • Unused lifting rails can make the cabinet look incomplete or industrial – removal improves aesthetic integration.
  1. Ensuring Electrical Insulation
  • The plastic caps ensure the cabinet remains fully insulated, maintaining safety standards.
  • This prevents unintended conductivity and enhances the cabinet’s overall durability.

A Smarter, Safer Way to Install Heavy Cabinets

The PVC Cabinet is designed with integrated safety features, including lifting rails for easy installation. By following safe lifting and mounting techniques, it is possible to:

  • Prevent cabinet damage and workplace injuries.
  • Ensure a secure, stable installation.
  • Maintain electrical insulation with the correct finishing touches.

By prioritising proper equipment, training, and communication, lifting and installing the PVC Cabinet can be handled safely and efficiently every time.

More Posts

Blog Categories
Archives
TOP

Make an enquiry

Get in touch to make an enquiry about any of our products.

What rating are the chargers you are looking for the feeder pillar to power?
Please specify another rating.
Please specify number of chargers.
Would you prefer a Stainless Steel or a PVC feeder pillar?
If GRP is required, the PVC Feeder Pillar is electrically insulated and a suitable alternative for GRP.

Incoming DNO Specification

Please specify Supply Current in Amps.
Please specify cable area in mm2.
Please specify cable core: triple, copper, hybrid, etc.
What earthing choice would you prefer?
Which type of fault protection equipment do you require?
Do you require empty space for DNO equipment inside the feeder pillar?

Outgoing Specification

Which type of fault protection equipment do you require?
Do you require any of the following additional equipment inside the feeder pillar? Check all that apply.
Check any options that apply.
Please add any other electrical component options.
Do you require a power supply to anything outside the feeder pillar (not including the chargers) e.g. Lighting, CCTV ?

Contact Details

Please provide contact details so we can get in touch with a quote for your EV requirements.
Name
=
Following this submission, we will send you an opt-in email to confirm your consent. You can also unsubscribe at any time.

Contact Info