Have you found the right Power Supply Enclosure?

Our outdoor electrical enclosures are often called for when installing a new power supply connection.

We have an extensive range of pillars and cabinets, all suitable for an electrical connection. You will find them all under electrical enclosures, starting with the smaller cost effective R Pillars. These are root mounted feeder pillars with lift-off doors from the R range with three different sizes or opt for the hinged pillars which feature a full perimeter IP 46 door seal (again three sizes to choose from) from our RH Pillar range.

Moving onto bigger enclosures, our cabinets with optional plinths from the RB range are available in 6 sizes and in single and double door versions, all feature a single compartment fitted with wooden backboards for electrical equipment.

Specifically Designed Power Supply Enclosures

We designed and created, at Electricity North West’s request (our local DNO in the Northwest of England), four more types of enclosures which we have coined as Power Supply Enclosures. What sets these enclosures apart, is that they have segregated compartments. Each has individual backboards and can be locked independently. 

One side is for the consumer and the other compartment is for the electricity company (or what is also known as the DNO). They come in two sizes and are for permanent or temporary electrical connections.

Permanent Power Supply Enclosures

The Permanent Enclosures are the PS60 and PS300, these cabinets are usually powder coated green (but can be painted in any of our standard colours). The PS60 is a smaller enclosure or kiosk that is 1250mm wide by 1266mm high with a depth of 430mm. The two compartments are approximately 620 wide x 1000 high. Typically suitable for electrical connections of up to 60 kVA.

PS60 Permanent Supply Cabinet - Double Door Kiosk for Power Supply Connections
PS60 Enclosure

The PS300 is a larger two compartment kiosk, with external dimensions of 1600mm wide x 2307mm high and 800mm deep. The two compartments are approximately 750 x 2000 high. Typically suitable for electrical connections of 300 kVA.

PS300 Permanent Supply Kiosk in Dark Grey Finished Installation
An installed PS300 Enclosure in Dark Grey (Standard Colour).

Temporary Power Supply Enclosures

The temporary enclosures are the TBS60 and TBS300. They are the same size and design, except that we paint the Temporary Builders Supply enclosures red because of their temporary nature. The red makes them stand out as a temporary item on a construction site. This is compulsory if you are installing a temporary connection in an Electricity North West (ENW) area as this is their requirement. 

 

The TBS60 is a smaller enclosure or kiosk that is 1250mm wide by 1266mm high with a depth of 430mm. The two compartments are approximately 620 wide x 1000 high. Typically suitable for electrical connections of up to 60 kVA.

The TBS60 has one more advantage we’d like to point out, our cabinets are made from durable stainless steel which is made to take wear and tear and for this reason, the TBS60 size can be used again, at another location after its first use. This is especially true for the TBS60 due to its temporary nature, after its been used, it can go on to the next site. The enclosure is strong enough and easy enough to transport and handle on-site. Making the TBS60 a very cost effective solution for use on various building sites or on a large construction site to power different areas as works progress.

 

TBS60 Temporary Builders Supply Cabinet - TBS60 Cabinet in Red
TBS60 Kiosk

The TBS300 is a larger 2 compartment kiosk, with external dimensions of 1600mm wide x 2307mm high and 800mm deep. The two compartments are approximately 750 x 2000 high. Typically suitable for electrical connections of 300kVA.

TBS300 (Temporary Builders Supply Kiosk) 300 in Red with Closed Door
TBS300 Kiosk

RB Cabinets for Power Supply Connections

Perhaps our Power Supply enclosures are too big or there is no need for two compartments.  In this case, we suggest browsing through our RB Cabinet range, for single and double door enclosures fitted with a plywood backboard for mounting electrical equipment.

For a single-phase supply to a building, we would normally recommend the smaller RB600 or RB800 Cabinet as the most cost-effective solution.

RB800 used for electrical connection for a village green
RB800 Cabinet housing a metered supply and separate sockets for electrical supply to the village green.

Large Enclosures for Power Supplies

If perhaps the larger Power Supply Enclosures don’t fit the bill, see our larger Ritherdon Modular Cabinets, our RMC enclosures. The sizes available may be better suited for your application. These are our largest enclosures, with a single bay with no internal separation with a fitted plywood backboard. 

RMC1600 Cabinet being delivered on site. It is a tall green cabinet

Still Unsure? – Give us Dimensions

Make sure to get the external dimensions of the enclosure – height, width and depth and we can point you to the closest size. If you take the backboard size, that will also help. Make sure you know what depth you require for the electrical equipment you will place inside the enclosure.

To make sure you are selecting the correct enclosure, we advise that you check with your DNO when considering a new connection. They will advise on the requirements for new connections, including the requirements for the enclosure.

Browse this website or our online shop and give us a call if you’re unsure.

More Posts

Blog Categories
Archives
TOP

Make an enquiry

Get in touch to make an enquiry about any of our products.

What rating are the chargers you are looking for the feeder pillar to power?
Please specify another rating.
Please specify number of chargers.
Would you prefer a Stainless Steel or a PVC feeder pillar?
If GRP is required, the PVC Feeder Pillar is electrically insulated and a suitable alternative for GRP.

Incoming DNO Specification

Please specify Supply Current in Amps.
Please specify cable area in mm2.
Please specify cable core: triple, copper, hybrid, etc.
What earthing choice would you prefer?
Which type of fault protection equipment do you require?
Do you require empty space for DNO equipment inside the feeder pillar?

Outgoing Specification

Which type of fault protection equipment do you require?
Do you require any of the following additional equipment inside the feeder pillar? Check all that apply.
Check any options that apply.
Please add any other electrical component options.
Do you require a power supply to anything outside the feeder pillar (not including the chargers) e.g. Lighting, CCTV ?

Contact Details

Please provide contact details so we can get in touch with a quote for your EV requirements.
Name
=
Following this submission, we will send you an opt-in email to confirm your consent. You can also unsubscribe at any time.

Contact Info