FireSeal providing over 60 min protection

The threat of fire in multi-occupancy dwellings is a major concern to landlords, councils and, of course, residents themselves. A fire can spread rapidly and unpredictably. But often there are breaches in critical walls that make way for ducting and other services, which can create deadly smoke pathways. Critical elements of fire safety can also be compromised by, for example, doors opening into service risers, plumbing access panels, and electricity meter boxes set into walls.

In the last of these dangers, once the meter box door has been damaged or removed, the wooden meter board may be the only barrier between the flat and the common corridor outside. 

Ritherdon technicians set their minds to the task of solving this potentially life-threatening problem – and re-instating acceptable fire resistance to these breaches. The result? The Ritherdon FireSeal, a fire and smoke resistant meter box door and frame unit.

The easy-to-fit steel unit with intumescent seals fits over the meter box and provides 60-minute fire protection, preventing the transmission of smoke and harmful fumes through any aperture the unit covers. 

BS 9999: 2008 recommends that elements in a multi-storey block should typically provide between 30 and 60 minutes fire resistance. The FireSeal easily reaches this standard when tested to EN 1363 and EN 1366, matching the performance of the fire doors normally used in flats.

FireSeal Design

The FireSeal is an adaptation of the existing range of Ritherdon meter box repair units. Higher temperature-resistant locks and stronger doors mean that it can be fitted to a wall to cover a variety of aperture shapes and sizes. The unit has a modified hinge design, allowing an intumescent seal to be added to all four sides of the door. A second intumescent seal between the frame of the FireSeal and the wall gives added smoke protection against potential smoke pathways. A high temperature resistant cam-lock completes the enhanced fire resistant design.

Fire Resistance Testing

The FireSeal was independently tested by Chiltern International Fire (now BM TRADA) to the method specified in EN 1363 and EN 1366 and was demonstrated to maintain its integrity as a barrier to fire penetration for at least 60 minutes up to almost 1000° C. The structural integrity of the units themselves was not compromised during testing, and once the units had cooled-down, the locks, hinges and doors still worked.

More than 2000 FireSeal units are already helping to improve fire safety in properties throughout the country.

More Posts

Blog Categories
Archives
TOP

Make an enquiry

Get in touch to make an enquiry about any of our products.

What rating are the chargers you are looking for the feeder pillar to power?
Please specify another rating.
Please specify number of chargers.
Would you prefer a Stainless Steel or a PVC feeder pillar?
If GRP is required, the PVC Feeder Pillar is electrically insulated and a suitable alternative for GRP.

Incoming DNO Specification

Please specify Supply Current in Amps.
Please specify cable area in mm2.
Please specify cable core: triple, copper, hybrid, etc.
What earthing choice would you prefer?
Which type of fault protection equipment do you require?
Do you require empty space for DNO equipment inside the feeder pillar?

Outgoing Specification

Which type of fault protection equipment do you require?
Do you require any of the following additional equipment inside the feeder pillar? Check all that apply.
Check any options that apply.
Please add any other electrical component options.
Do you require a power supply to anything outside the feeder pillar (not including the chargers) e.g. Lighting, CCTV ?

Contact Details

Please provide contact details so we can get in touch with a quote for your EV requirements.
Name
=
Following this submission, we will send you an opt-in email to confirm your consent. You can also unsubscribe at any time.

Contact Info