An Investigation into Ritherdon Cabinet Thermodynamics

Introduction

Here at Ritherdon we are always aiming to improve the performance of our products based on customer requirements, and one of the ways we do this is through in-house testing, which is part of Ritherdon’s commitment to the continuous improvement of our products and our business.

Earlier in the year, we carried out an investigation to determine how best to optimise the heat transfer out of Ritherdon cabinets with the aim of making our cabinets as versatile as possible.

Our cabinets house hardware ranging from networking equipment to power supplies, all of which generate heat during their use. During the hot season, the higher temperatures causes the equipment in the cabinets to overheat, tripping the temperature sensor and turning the equipment off.

Our cabinets are sold as standard with venting (placed on the sides), however if the customer desires a higher IP rating, the venting can be removed from the design, however this may impact on the cabinet thermodynamics. This investigation took into account both scenarios.

Experiment Overview

Experiments were carried out using ventilated cabinets and sealed cabinets containing a 400W heating element. Up to four 19W fans were used to circulate air around and extract air from the system to determine the most effective arrangement. A diagram of the rig can be found below.

Rig used to measure heat transfer to understand cabinet thermodynamics

 Each arrangement was tested over the course of a day and repeated once to obtain reliable results. The average inside cabinet temperature was measured continuously using eight thermocouples, the surface temperature was measured at 90 points, 6 times per test to calculate an average, and the ambient temperature was measured continuously using an ambient temperature sensor, all of which were used to calculate convective heat transfer coefficients.

Air flow and temperature in and out of the cabinet was measured and used to produce a heat and mass balance around the cabinet.

In-house testing of Ritherdon Cabinet Thermodynamics

Conclusions

The following conclusions were made from the experiment:

  • It was found that there was a limit to the overall heat transfer coefficient of approximately 4.1 W/m2K for sealed cabinets.
  • Stirring fans were found to have a similar effect to extraction fans when running in a sealed cabinet, despite the extraction fans running directly against a sealed surface.
  • Pure natural convection was found to be as effective as the use of a single stirring fan for a ventilated cabinet.
  • Stirring fans were found to have a negative effect when used in conjunction with extraction fans for a ventilated cabinet.
  • The lowest temperature difference was found to be 20°C, using two extraction fans at the top sides of the cabinet.
For a more detailed analysis of these conclusions, what they mean and how they were obtained, please read the full report.
 
In the coming months we hope to conduct more in-depth investigations into how we can best optimise the thermodynamic performance of our cabinets using the results we have obtained as a blueprint. 
 

More Posts

Blog Categories
Archives
TOP

Make an enquiry

Get in touch to make an enquiry about any of our products.

What rating are the chargers you are looking for the feeder pillar to power?
Please specify another rating.
Please specify number of chargers.
Would you prefer a Stainless Steel or a PVC feeder pillar?
If GRP is required, the PVC Feeder Pillar is electrically insulated and a suitable alternative for GRP.

Incoming DNO Specification

Please specify Supply Current in Amps.
Please specify cable area in mm2.
Please specify cable core: triple, copper, hybrid, etc.
What earthing choice would you prefer?
Which type of fault protection equipment do you require?
Do you require empty space for DNO equipment inside the feeder pillar?

Outgoing Specification

Which type of fault protection equipment do you require?
Do you require any of the following additional equipment inside the feeder pillar? Check all that apply.
Check any options that apply.
Please add any other electrical component options.
Do you require a power supply to anything outside the feeder pillar (not including the chargers) e.g. Lighting, CCTV ?

Contact Details

Please provide contact details so we can get in touch with a quote for your EV requirements.
Name
=
Following this submission, we will send you an opt-in email to confirm your consent. You can also unsubscribe at any time.

Contact Info